5120-00-188-3652 INSTALLING TOOL,SPO Index 6145-00-188-3654 CABLE,POWER,ELECTRICAL

National Stock Number:
6145-00-188-3653

Federal Supply Class:
6145

National Item Identification Number:
001883653

Description:
CABLE,POWER,ELECTRICAL

Detail:
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
0021706542FEDERAL STANDARDS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
1810316428BELDEN WIRE & CABLE COMPANY LLC DBA BELDEN CDT ELECTRONICS DIVISION
181032W733BELDEN WIRE AND CABLE CO WIRE AND CABLE OFFICE
J-C-58081348FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
J-C-580S6CK2/16SRSJ81348FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
TYPES600-16-206542FEDERAL STANDARDS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
UL 6281345UNDERWRITERS LABORATORIES INC
UL62S00W6BCK2/16EPCPE81345UNDERWRITERS LABORATORIES INC
UL62SOOW6BCK2/16EPCPE81345UNDERWRITERS LABORATORIES INC


Techincal Specification:
COLORBLACK 1ST POSITION COVER FIRST CONDUCTOR
COLORWHITE 2ND POSITION COVER SECOND CONDUCTOR
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
CONDUCTOR ARRANGEMENT AND QUANTITY2 SINGLES
CONDUCTOR QUANTITY2
CROSS SECTION OUTSIDE DIAMETER0.400 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLEROUND
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATERIALRUBBER SYNTHETIC 1ST POSITION JACKET CABLE
MATERIALRUBBER SYNTHETIC 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
ROUND CONDUCTOR SIZE16 AWG ALL CONDUCTORS
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR34 ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR65 ALL CONDUCTORS
TEMP RATING60.0 CELSIUS