Description:
POWER SUPPLY

Detail:
A COMPONENT WHICH CONVERTS AVAILABLE ALTERNATING CURRENT OR DIRECT CURRENT ELECTRICAL POWER INTO A FORM REQUIRED TO OPERATE ANOTHER COMPONENT OR SET. THE ITEM MAY CONSIST OF A COMBINATION OF AN INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; WITH A TRANSFORMER AND RECTIFIER(S) EMPLOYING ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE COMPONENTS, OR THE SYNCHRONIZED SECONDARY CONTACT(S) OF A VIBRATOR, SELF-RECTIFYING; OR MAY CONSIST OF ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE RECTIFIERS AND CAPACITORS IN TRANSFORMERLESS (ALTERNATING CURRENT-DIRECT CURRENT TYPE) CIRCUITS WHICH MAY BE OF THE VOLTAGE-MULTIPLIER TYPE. THE ITEM MAY INCORPORATE A FILTER, DIRECT CURRENT POWER AND PROVISIONS FOR REGULATION OF INPUT AND/OR OUTPUT VOLTAGE. EXCLUDES BATTERY CHARGERS; ROTATING MACHINERY TYPES; SUCH AS MOTOR GENERATORS AND DYNAMOTORS, POWER SUPPLY, CAUTERY APPARATUS; POWER SUPPLY, ELECTRODIAGNOSTIC INSTRUMENTS, AND POWER SUPPLY, MOBILE RESPIRATOR.


Manufacturer Information:
PCX40-0-5C85604KEPCO, INC.
PCX40-0-5MAT W/CASE CA385604KEPCO, INC.


Techincal Specification:
INPUT VOLTAGE RATING210.0 AC VOLTS MINIMUM AND
250.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT
105.0 DC VOLTS MINIMUM AND
125.0 DC VOLTS MAXIMUM 2ND OPERATING POWER RQMT
OVERALL LENGTH16.906 INCHES NOMINAL
OUTPUT VOLTAGE RATING40.0 DC VOLTS MAXIMUM SINGLE POWER OUTPUT
OUTPUT CURRENT RATING500.0 DC MILLIAMPERES MAXIMUM SINGLE POWER OUTPUT
RECTIFICATION METHODSINGLE PHASE FULL WAVE CENTER TAP
OUTPUT CONTROL TYPEVOLTAGE ADJUSTMENT SINGLE POWER OUTPUT
OUTPUT CONTROL QUANTITY1 SINGLE POWER OUTPUT
OUTPUT CONNECTION QUANTITY2 SINGLE POWER OUTPUT
OUTPUT CONNECTION TYPECONNECTOR, PLUG SINGLE POWER OUTPUT
ELECTRICAL POWER SOURCE RELATIONSHIPOPERATING
INPUT FREQUENCY RATING50.0 HERTZ MINIMUM AND
440.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT
50.0 HERTZ MINIMUM AND
440.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT
INPUT PHASESINGLE 1ST OPERATING POWER RQMT
SINGLE 2ND OPERATING POWER RQMT
VENTILATION DESIGN TYPEAMBIENT AIR
OVERALL WIDTH4.219 INCHES NOMINAL
OVERALL HEIGHT2.688 INCHES NOMINAL
OPERATING AMBIENT TEMP RANGE-20.0 TO 65.0 DEG CELSIUS
FEATURES PROVIDEDEMI FILTER
THE MANUFACTURERS DATA
MANUFACTURERS CODE85604
DESIGN CONTROL REFERENCEPCX40-0-5MAT W/CASE CA3