CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES SINGLE CONNECTION FACILITY |
FLANGE CONNECTING HOLE DIAMETER | 0.144 INCHES MINIMUM AND 0.147 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
FLANGE INSIDE HEIGHT | 0.394 INCHES MINIMUM AND 0.396 INCHES MAXIMUM ALL FLANGES |
FLANGE DEPTH | 0.298 INCHES MINIMUM AND 0.328 INCHES MAXIMUM ALL FLANGES |
FLANGE INSIDE WIDTH | 0.705 INCHES MINIMUM AND 0.707 INCHES MAXIMUM ALL FLANGES |
FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM FIRST FLANGE |
FLANGE OUTSIDE HEIGHT | 1.328 INCHES MAXIMUM SECOND FLANGE |
FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM AND 1.328 INCHES MAXIMUM ALL FLANGES |
FLANGE QUANTITY | 2 |
FLANGE STYLE | COVER TYPE ALL FLANGES |
FLEXIBILITY | RIGID ALL TUBING SEGMENT |
FSC APPLICATION DATA | TEST SET,COMPUTER,SPECIALLY DESIGNED,ACFT |
MATERIAL | COPPER ALLOY ALL TUBING SEGMENT |
PRECIOUS MATERIAL AND LOCATION | FLANGE SURFACE SILVER |
PRECIOUS MATERIAL | SILVER |
SPECIAL FEATURES | W/ATTENUATOR COLLAR LOCATED AT CENTER OF WAVEGUIDE LENGTH |
WAVEGUIDE INSIDE HEIGHT | 0.309 INCHES MINIMUM AND 0.313 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 0.620 INCHES MINIMUM AND 0.624 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE WIDTH | 0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM |
WAVEGUIDE LENGTH | 2.500 INCHES NOMINAL |
STYLE DESIGNATOR | STRAIGHT TYPE |
SURFACE TREATMENT | PAINT ALL TUBING SEGMENT OUTSIDE SURFACES |
SURFACE TREATMENT | SILVER AND PAINT ALL FLANGE OUTSIDE SURFACES |
SURFACE TREATMENT | SILVER ALL TUBING SEGMENT INSIDE SURFACES |
TUBING WALL CONSTRUCTION STYLE | SEAMLESS ALL TUBING SEGMENT |