5905-00-211-1403 RESISTOR,FIXED,WIRE WOUND Index 5999-00-211-1410 GASKETING MATERIAL,CONDUCTIVE

National Stock Number:
5950-00-211-1408

Federal Supply Class:
5950

National Item Identification Number:
002111408

Description:
TRANSFORMER,CURRENT

Detail:
An item consisting of one or more windings, designed to be placed near or connected in series with an alternating current power line to measure the current passing through the line by means of a meter; or to control the current passing through the line by means of a control device. Excludes TRANSFORMER, POWER, CURRENT REGULATING.


Manufacturer Information:
00000-492979343ASRC FEDERAL FACILITIES LOGISTICS, LLC
00000-492993568HARSCO CORP BMY-COMBAT SYSTEMS DIV
71-489230554DEPARTMENT OF DEFENSE PROJECT MANAGER-MOBILE ELECTRIC POWER


Techincal Specification:
BODY HEIGHT4.500 INCHES NOMINAL
BODY LENGTH5.000 INCHES NOMINAL
BODY WIDTH3.250 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
INSTALLATION FOR WHICH DESIGNEDINDOOR PORTABLE
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODFLANGE AND SLOT SINGLE GROUP
MOUNTING SLOT WIDTH0.220 INCHES NOMINAL SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT
WINDING OPERATING CURRENT7.4 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE35.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
TERMINAL TYPE AND QUANTITY2 THREADED STUD