5950-00-194-6798 TRANSFORMER,POWER Index 4920-00-194-6803 FIXTURE,AIRCRAFT MAINTENANCE

National Stock Number:
5950-00-194-6799

Federal Supply Class:
5950

National Item Identification Number:
001946799

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
K901013GP50121921RCA CORP DISTRIBUTOR AND SPECIAL PRODUCTS DIV
K901013GP50149671LOCKHEED MARTIN CORP LOCKHEED MARTIN INFORMATION SYSTEMS AUTOMATED SPARES


Techincal Specification:
BODY HEIGHT5.156 INCHES NOMINAL
BODY LENGTH4.188 INCHES NOMINAL
BODY WIDTH3.938 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODFLANGE AND UNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT1.2 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT3.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT11.1 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT120.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE110.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE17.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE5.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE550.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY15 STANDOFF INSULATOR