5342-00-189-6691 MOUNT,RESILIENT,WEAPON SYSTEM Index 5940-00-189-6697 TERMINAL BOARD

National Stock Number:
5950-00-189-6692

Federal Supply Class:
5950

National Item Identification Number:
001896692

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1023670918876U S ARMY AVIATION AND MISSILE COMMAND
A748505584AUTODYNE MANUFACTURING CO INC
BX-922485323BALTIMORE TRANSFORMER CO
C772172149ELECTRONIC TRANSFORMER CORP
SAFA1611850MAGNETIKA/EAST LTD TITAN TRANSFORMER DIV
TT714411850MAGNETIKA/EAST LTD TITAN TRANSFORMER DIV


Techincal Specification:
BODY HEIGHT1.625 INCHES MINIMUM AND 1.750 INCHES MAXIMUM
BODY LENGTH1.187 INCHES MINIMUM AND 1.312 INCHES MAXIMUM
BODY WIDTH1.187 INCHES MINIMUM AND 1.312 INCHES MAXIMUM
DISTANCE BETWEEN MOUNTING FACILITY CENTERS0.984 INCHES MINIMUM AND 1.016 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING5.0 KILOHERTZ MINIMUM AND 6.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT2.050 INCHES MAXIMUM
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
MOUNTING METHODTHREADED HOLE SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT30.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT500.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE105.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 125.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE22.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE27.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
TERMINAL TYPE AND QUANTITY8 TURRET
THREAD QUANTITY PER INCH32 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP