5925-00-174-0432 CIRCUIT BREAKER Index 5345-00-174-0445 STONE,COMMUTATOR SURFACING

National Stock Number:
5925-00-174-0434

Federal Supply Class:
5925

National Item Identification Number:
001740434

Description:
CIRCUIT BREAKER

Detail:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.


Manufacturer Information:
17639930086L3HARRIS MARITIME POWER & ENERGY SOLUTIONS, INC.
700099SH830086L3HARRIS MARITIME POWER & ENERGY SOLUTIONS, INC.
MILC17587TYPEACB64081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ACTUATOR FUNCTIONRESET
ARC QUENCHING METHODMAGNETIC BLOWOUT
CIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH8.000 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH13.000 INCHES NOMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 DC ALL LOCATIONS
OVERALL HEIGHT19.750 INCHES NOMINAL
OVERALL LENGTH24.000 INCHES NOMINAL
OVERALL WIDTH13.000 INCHES NOMINAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITY1 ROTARY
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE480.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS25000.0 DC ALL LOCATIONS
MOUNTING FACILITY TYPE AND QUANTITY6 UNTHREADED HOLE
POLE QUANTITY2
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSAS DIFFERENTIATED BY THE POLE,AC RATING,INTERRUPTING CAPACITY,CIRCUIT PROTECTION,TRIPPING CURRENT,O/A DIM,MTG HOLES,TERMINALS AND SHORT TIME DELAY SETTING 1,280 AMP,TIME BAND NO. 3
RESET METHODMANUAL
SPECIAL FEATURESAUXILIARY SWITCH INCLUDED,TRIPS INSTANTANEOUSLY AT 2.500 AMPS
TRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
TRIP RELEASE METHODMAGNETIC ALL LOCATIONS
UNTHREADED MOUNTING HOLE DIAMETER0.563 INCHES NOMINAL