5910-00-188-9054 CAPACITOR,FIXED,PAPER DIELECTRIC Index 5910-00-188-9062 CAPACITOR,FIXED,PAPER DIELECTRIC

National Stock Number:
5915-00-188-9057

Federal Supply Class:
5915

National Item Identification Number:
001889057

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
2664795-210001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
2664795-249956RAYTHEON COMPANY
7BC165-4-3-3EE23042TRILITHIC, INC.
TBA165-4-3-1-7CC104423TELONIC BERKELEY, INC.


Techincal Specification:
BODY OUTSIDE DIAMETER0.780 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS80.0 MINIMUM BLANK AND 3.0 NOMINAL BLANK 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION163.75 MEGAHERTZ BLANK AND 167.05 MEGAHERTZ BLANK
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK
INPUT TERMINAL IDENTIFICATIONTNCFEMALE
INPUT TERMINAL MANUFACTURER CODE10001
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS7.5 BLANK
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK
OUTPUT TERMINAL IDENTIFICATIONTNCFEMALE
OUTPUT TERMINAL MANUFACTURER CODE10001
OVERALL LENGTH10.500 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL
OPERATING TEMP RANGE+5.0 TO 65.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION165.4 MEGAHERTZ BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION135.336 MEGAHERTZ BLANK AND 163.75 MEGAHERTZ BLANK AND 167.05 MEGAHERTZ BLANK AND 195.464 MEGAHERTZ BLANK
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION164.41 MEGAHERTZ BLANK AND 166.39 MEGAHERTZ BLANK
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES


Click here to Register for Free 30-day Trial