5935-00-220-3405 CONNECTOR,RECEPTACLE,ELECTRICAL Index 5910-00-220-3408 CAPACITOR,FIXED,MICA DIELECTRIC

National Stock Number:
5910-00-220-3407

Federal Supply Class:
5910

National Item Identification Number:
002203407

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
10128112A486GNIMIKKEISTOKESKUS NCB FINLAND
164102K0656BAE SYSTEMS (OPERATIONS) LIMITED
2606431-7706424ALLIANT TECHSYSTEMS OPERATIONS LLC
352250008311H0203THALES NEDERLAND B.V.
416977-4096214RAYTHEON COMPANY
420-102-003A1997ELETTRONICA SPA
420-102-003C3141ELETTRONICA GMBH
5N5224-001-10D1901HENSOLDT SENSORS GMBH
A1224449F9111THALES AVS FRANCE SAS
B99304-41K0268RAYTHEON SYSTEMS LIMITED
CK06BX224K81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CK06BX224KU1753ITW LIMITED
MILC11015-1981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY HEIGHT0.090 INCHES NOMINAL
BODY LENGTH0.290 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY WIDTH0.290 INCHES NOMINAL
CAPACITANCE VALUE PER SECTION0.220 MICROFARADS SINGLE SECTION
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.185 INCHES MINIMUM AND 0.215 INCHES MAXIMUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT2.5000
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP1000.0 MEGOHM-MICROFARADS
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
MATERIALPLASTIC CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION50.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE-15.0 TO 25.0 WITH RATED VOLTAGE APPLIED SINGLE SECTION
TERMINAL LENGTH1.250 INCHES MINIMUM
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-11015+19 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial