4820-00-188-8247 VALVE,GLOBE Index 3020-00-188-8251 LINK,OFFSET

National Stock Number:
4820-00-188-8248

Federal Supply Class:
4820

National Item Identification Number:
001888248

Description:
VALVE,GLOBE

Detail:
A valve with one inlet and one outlet connection with outlet flow parallel to inlet flow. The flow is controlled by the action of a stem which lifts the disk perpendicularly off the center axis of its seat. The stem is at a 90 degree (1.5708 radians) angle to axis of flow. Excludes VALVE, STOP-CHECK; COCK, SHUTOFF, SCREW STEM; and VALVE, SOLENOID.


Manufacturer Information:
161AC402L 1476364MILWAUKEE VALVE CO, INC
260WS1-4SEAT63686THE WALWORTH COMPANY
4DP2036APC7-1-463686THE WALWORTH COMPANY
571-3803-1303218PCV753711NAVAL SEA SYSTEMS COMMAND
571-4805-1303336PCV853711NAVAL SEA SYSTEMS COMMAND
571-8700-1302720PCV153711NAVAL SEA SYSTEMS COMMAND
803-438453680064NAVAL SHIP SYSTEMS COMMAND
803-4384536-11A80064NAVAL SHIP SYSTEMS COMMAND
803-4384536-11AXAF80064NAVAL SHIP SYSTEMS COMMAND
810-138572280064NAVAL SHIP SYSTEMS COMMAND
810-438453680064NAVAL SHIP SYSTEMS COMMAND
810-4384536-11A2280064NAVAL SHIP SYSTEMS COMMAND
C-35298M-1/4IN76364MILWAUKEE VALVE CO, INC


Techincal Specification:
BONNET ATTACHMENT METHODTHREADED
BONNET TYPEINSIDE SCREW
CONNECTION STYLEPLAIN (PIPE) ALL ENDS
CONNECTION TYPETHREADED EXTERNAL PIPE ALL ENDS
FLOW CONTROL DEVICEDISK
MATERIALCOPPER ALLOY 922 BODY
MATERIALNICKEL ALLOY FLOW CONTROL DEVICE
MATERIALNICKEL ALLOY SEAT
MATERIALNICKEL ALLOY STEM
MATERIALRUBBER PACKING
MAXIMUM OPERATING PRESSURE200.0 POUNDS PER SQUARE INCH SINGLE RESPONSE
MAXIMUM OPERATING TEMP425.0 FAHRENHEIT SINGLE RESPONSE
MEDIA FOR WHICH DESIGNEDSTEAM SINGLE RESPONSE
NOMINAL THREAD SIZE0.250 INCHES ALL ENDS
RENEWABLE SEAT RING TYPETHREADED
STYLE DESIGNATORSTRAIGHT THRU
TEST DATA DOCUMENT03950-882057048 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
THREAD DIRECTIONRIGHT-HAND ALL ENDS
THREAD SERIES DESIGNATORNPT ALL ENDS
VALVE OPERATION METHODMANUAL