 ACQUISITION METHOD CODE. | 'All Departments | 1 | SUITABLE FOR COMPETITIVE ACQUISITION. |
| ACQUISITION METHOD SUFFIX CODE. | 'All Departments | G | THE GOVERNMENT HAS UNLIMITED RIGHTS TO THE TECHNICAL DATA AND THE DATA PACKAGE IS COMPLETE. VALID AMCS: 1 AND 2. |
| MAJOR ORGANIZATIONAL ENTITY. | Army | DA | Army | Defense Logistics Agency. | DS | Defense Logistics Agency. |
| PRICE | Defense Logistics Agency. | Price | 4.16 | Army | Price | 4.87 |
| PRECIOUS METALS INDICATOR CODES. | All Departments | A | Item does not contain Precious Metal. |
| CRITICALITY CODE. | All Departments | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| AUTOMATIC DATA PROCESSING EQUIPMENT. | | ELECTROSTATIC DISCHARGE CODE. | | HAZARDOUS MATERIALS INDICATOR CODE. | All Departments | N | Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials. |
| DEMILITARIZATION CODE. | All Departments | A | No-USML/Non-CCLI – No DEMIL or DoD TSC required. Department of Commerce may impose licensing requirements to certain destinations. (Note 9). |
| For additional information Register for Free Trial |
|  | | THREAD COTTON, SOFT FINISH, Z-TWIST, OLIVE DRAB 66022 (S-1), TICKET NO. 10, 3 PLIES MILDEW RESISTANT, MIL-T-3530, TYPE I CLASS I FOR TREATMENT, TYPE IIIA FOR THREAD, 2660 YARDS PACKAGE. ADDITIONAL INFORMATION FOR A-A-52094: . THE THREAD SHALL BE IN ACCORDANCE WITH SPECIFICATION A-A-52094A, DATED 30 MARCH 2007 . ADDITIONAL INFORMATION FOR PPP-B-636: FEDERAL SPECIFICATION PPP-B-636 DATED JULY 12, 1981, INCLUDING INTERIM FEDERAL SPECIFICATION PPP-B-636L DATED JANUARY 1, 1991, IS HEREBY CANCELLED, AND REPLACED WITH ASTM-D-5118, STANDARD PRACTICE FOR FABRICATION OF FIBERBOARD SHIPPING BOXES, AND ASTM-D-1974, STANDARD PRACTICE FOR METHOD OF CLOSING, SEALING AND REINFORCING FIBERBOARD SHIPPING CONTAINERS. INSPECTION OF SUPPLIES SHALL BE IN ACCORDANCE WITH FAR PART 52.246-2 STANDARD INSPECTION. ADDITIONAL INFORMATION FOR MIL-STD-105E: MIL-STD-105E, dated 10 May 1989, is hereby canceled. Future acquisitions may refer to: MIL-STD-1916, "DoD Preferred Methods for Acceptance of Product", or ANSI/ASQ Z1.4, "Sampling Procedures and Tables for Inspection by Attributes". Users are cautioned to evaluate these documents for their particular application before citing it as a replacement document. (Copies of MIL-STD-1916 are available online at http://assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) (Copies of ANSI/ASQ Z1.4 are available online at www.asq.org or ASQ Distribution Center, 5131 S. Third Street, Milwaukee, Wisconsin 53207-6028.) MIL-STD-129P, WITH CHANGE 4 - DEPARTMENT OF DEFENSE STANDARD PRACTICE MILITARY MARKING FOR SHIPMENT AND STORAGE - DATED 19 SEPTEMBER 2007 INTERIM CHANGES: OMISSION OF MARKINGS ON EXTERIOR SHIPPING CONTAINERS OF ITEMS IN THE DLA TROOP SUPPORT CLOTHING AND TEXTILE (C&T) DIRECTORATE: THE NOMENCLATURE AND MANUFACTURER'S NAME (WHEN THE NAME IDENTIFIES THE MATERIAL) SHALL BE OMITTED FROM ALL EXTERIOR SHIPPING CONTAINERS OF DLA TROOP SUPPORT C&T ITEMS, REGARDLESS OF MODE OF SHIPMENT. IF THE MANUFACTURER'S NAME DOES NOT IDENTIFY THE MATERIAL AS BEING CLOTHING, IT MAY REMAIN. NSNS SHALL BE SHOWN ON ALL SHIPPING CONTAINERS OF C&T ITEMS, THE PACKING LIST SHALL BE PLACED INSIDE THE LAST CONTAINER TO BE LOADED FOR EACH SHIPMENT. THE WORDS "PACKING LIST HERE" SHALL BE STENCILED, NOT HAND LETTERED, ON THE CONTAINER. MIL-STD-147 IS HEREBY REINSTATED AS FOLLOWS: MIL-STD-147E DEPARTMENT OF DEFENSE 16 MAY 2008 STANDARD PRACTICE PALLETIZED UNIT LOADS STANDARDS (COMMERCIAL) ASME-MH1 American Society of Mechanical Engineers (ASME) Pallets, Slip Sheets, and Other Bases For Unit Loads, for construction of pallets. ADDITIONAL INFORMATION FOR MIL-STD-2073-1: . NO ADDITIONAL INFORMATION FOLLOWS (Ref. T0898) ADDITIONAL INFORMATION FOR FED-STD-191: FED-STD-191A NOTICE 7, DATED AUGUST 9, 2000 IS HEREBY INACTIVE FOR NEW DESIGN. WHEN NOT USING FED-STD-191, SEE INTERIM CHANGES TO END ITEM SPECIFICATION FOR REPLACEMENT ASTM. INTERIM CHANGES TO FED-STD-191A: TEST METHOD 5202, PARA. 5.3, DELETE FIRST SENTENCE AND SUBSTITUTE: "THE SPECIMEN SHALL BE CLAMPED FIRMLY, WITH ONE END FLUSH WITH THE OUTER EDGE OF THE VISE, SUCH THAT ONE INCH OF SPECIMEN LIES WITHIN THE CLAMP AND ONE INCH OF THE SPECIMEN EXTENDS BEYOND THE CENTER OF ROTATION (FACE OF THE VISE), AND WITH THE LONG EDGE PARALLEL TO THE FACE OF THE DIAL PLATE". TEST METHOD 5309.1 ABRASION RESISTANT OF TEXTILE WEBBING. PAGE 1, PARA 4.1.2,LINE 4: DELETE "B-97" AND SUBSTITUTE "B-91". THE FOLLOWING METHODS ARE IDENTIFIED AS SPECIFYING OZONE DEPLETING SUBSTANCES: 1100, 1200, 1240, 1400, 1410, 1500, 1510,1520,1530, 1540, AND 1550. PARA 5.1 OF THESE TEST METHODS REQUIRE THE USE OF 1,1,1- TRICHLOROETHANE, ALCOHOL OR ETHER. 1,1,1-TRICHLORETHANE IS AN OZONE DEPLETING SUBSTANCE (METHYL CHLOROFORM) AND IS THEREFORE PROHIBITED. THE USE OF EITHER ALCOHOL OR ETHER IS REQUIRED WHEN THESE METHODS ARE IN BASIC OR ANY REFERENCED DOCUMENT. METHOD 5202, STIFFNESS OF CLOTH, DIRECTIONAL; CANTILEVER BENDING METHOD. PAGE 2, PARA. 5.3 DELETE FIRST SENTENCE AND SUBSTITUTE WITH THE FOLLOWING: "THE SPECIMEN SHALL BE CLAMPED FIRMLY, WITH 1 END FLUSH WITH THE OUTER EDGE OF THE VISE, SUCH THAT 1" OF THE SPECIMEN LIES WITHIN THE CLAMP AND 1" OF THE SPECIMEN EXTENDS BEYOND THE CENTER OF ROTATION (INNER FACE OF THE VISE) AND WITH THE LONG EDGE PARALLEL TO THE FACE OF THE DIAL PLATE." METHOD 5556.1, MOBILE LAUNDRY EVALUATION FOR TEXTILE MATERIALS, PAGE 5, PARA. 5.2.2, LINE 8: DELETE SENTENCE BEGINNING WITH "THE SPECIMENS AND BALLAST" IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING: "THE SPECIMENS AND BALLAST SHALL BE SEPARATED, OPENED TO FULL WIDTH AND PLACED IN A PRE-HEATED DRYER HAVING A STACK TEMPERATURE OF 140-180 DEG. F. THIS TEMPERATURE RANGE CORRESPONDS TO A SETTING OF "HIGH" ON THE TEMPERATURE INDICATOR ON THE DRYER. DRYING SHALL CONTINUE FOR 45-60 MINUTES OR UNTILSAMPLES ARE DRY IN A ROTATING TUMBLE DRYER." PAGE 5, PARA. 5.2.3, LINE 8: DELETE SENTENCE BEGINNING WITH "THE SPECIMENS AND BALLAST" IN ITS ENTIRETY AND SUBSTITUTE WITH THEFOLLOWING: "THE SPECIMENS AND BALLAST SHALL BE SEPARATED, OPENED TO FULL WIDTH AND PLACED IN A PRE-HEATED DRYER HAVING A STACKTEMPERATURE OF 140-180 DEG. F. THIS TEMPERATURE RANGE CORRESPONDS TO A SETTING OF "HIGH" ON THE TEMPERATURE INDICATOR ON THE DRYER. DRYING SHALL CONTINUE FOR 35-40 MINUTES OR UNTIL SAMPLES ARE DRY." METHOD 5931, ELECTROSTATIC DECAY OF FABRICS; DETERMINATION OF PAGE 1, PARA. 3: AFTER NUMBER OF DETERMINATIONS ADD "PER SAMPLE UNIT". PAGE 1, PARA. 4: DELETE "APPARTUS" AND SUBSTITUTE "APPARATUS". PAGE 1, PARA. 5.1, LINE 3: AFTER "AT" DELETE"APPROXIMATELY". PAGE 2, PARA. 5.2, LINES 2, AND 5: AFTER "OF" ADD "+-". LINE 6: AFTER "TO" ADD "+-". PAGE 2, PARA. 5.3: DELETE IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING:"5.3 MOUNT A SPECIMEN TIGHTLY ACROSS THE ELECTRODES, CENTERING IT OVER THE SENSOR OPENING. THE SURFACE OF THE TEST SPECIMEN (BACK OR FRONT) SHALL FACE THE SENSOR. RECORD (OPTIONAL) THE RESIDUAL CHARGE LEVEL ON THE SAMPLE AS SEEN BY THE SENSOR, INCLUDING POLARITY. NOTE THAT TEST SAMPLES WITH THE RESIDUAL CHARGE LEVELS OF LESS +500 VOLTS YIELD THE BEST RESULTS. APPLY +5000 VOLTS TO THEELECTRODES FOR A PERIOD OF 20 SECS. AT THE END OF THE 20 SECOND PERIOD, THE HIGH VOLTAGE (5000 VOLTS) SHALL BE TURNED OFF ANDTHE SPECIMENS IMMEDIATELY GROUNDED. THE VOLTAGE BEHAVIOR OF THE SPECIMEN WITH RESPECT TO TIME SHALL BE PLOTTED ON THE RECORDER. NOTE: IN SOME CASES, THE TEST EQUIPMENT WILL DISPLAY VOLTAGE AND DECAY TIME INFORMATION AND A CHART RECORDER IS NOT NECESSARY." PAGE 2, PARA. 5.4, LINE 3: DELETE SENTENCE BEGINNING WITH "IF THE SPECIMEN DID" IN ITS ENTIRETY. PAGE 2, PARA. 5.5: DELETE PARAGRAPH IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING: "RECORD THE MAXIMUM VOLTAGE LEVEL(INCLUDING POLARITY) AND DECAY TIME TO 10% OF THE MAXIMUM VOLTAGE LEVEL ACHIEVED." PAGE 2, PARA. 5.6, LINE 1: ADD THE FOLLOWING PRIOR TO 1ST SENTENCE: "REVERSE VOLTAGE POLARITY REPEAT MEASUREMENT, ANDRECORD RESULTS." PAGE 3, PARA. 6.6: DELETE PARAGRAPH IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING: "THE AVERAGE TIME TO DECAY TO 10%OF THE MAX VOLTAGE SHALL BE INCLUDED FOR EACH OF THE WARP & FILLING DIRECTIONS, AS WELL AS THE OVERALL AVERAGE, FOR EACHFABRIC TESTED. THESE WILL BE OBTAINED BY AVERAGING THE TEST RESULTS (ABSOLUTE VALUE OF) TOGETHER FOR BOTH VOLTAGEPOLARITIES. UNLESS OTHERWISE STATED IN THE REQUIREMENTS DOCUMENT, THE FABRIC SHALL BE CONSIDERED ACCEPTABLE IF THEAVERAGE MAXIMUM VOLTAGE IN BOTH THE WARP AND FILLING DIRECTIONS IS LESS THAN 4000 VOLTS, AND THE AVERAGE DECAY TIME (TO 10% MAXVOLTAGE) IS GREATER THAN 0.5 SECONDS IN BOTH THE WARP AND FILLING DIRECTIONS. IT SHALL BE INDICATED WHETHER THE FABRIC ISACCEPTABLE OR NON-ACCEPTABLE." PAGE 3, PARA. 7.1, SECOND COLUMN, LINE 2: DELETE 406C AND SUBSTITUTE WITH "406D". AFTER PARA. 7.1, ADD THE FOLLOWING: "7.2 NOTE: IF THE MODEL 406D STATIC DECAY METER, OR EQUIVALENT, IS USED, A CHART RECORDER ISNOT MANDATORY FOR THE TEST." (Ref. |
|
| | MIL-STD-105E NOT 2 | AST | BASIC | | 10/03/2006 | 10/03/2006 | | MIL-STD-129P(3) | AST | BASIC | | 10/03/2006 | 10/03/2006 | | PPP-B-636J | AST | BASIC | | 10/03/2006 | 10/03/2006 | | FED-STD-191A(6) NOT 7 | AST | BASIC | | 10/03/2006 | 10/03/2006 | | A-A-52094A | AST | BASIC | | 10/03/2006 | 10/03/2006 | | PPP-B-636J(1) NOT 1 | AST | BASIC | | 10/03/2006 | 10/03/2006 | | MIL-STD-147D NOT 2 | AST | BASIC | | 10/03/2006 | 10/03/2006 | |
|
|